Reader setup
In the reader's panel: Settings > Integrations > Synchronization:
| Field | Value |
|---|---|
| Push punches to server | on |
| Format | http3 - UID as hex |
| Server URL | http://<your computer's IP>:8080/odbicia |
| Login / Password | rcp / the value of RCP_HASLO |
| Device ID (machineId) | any name, e.g. Gate |
| Interval [min] | 1 for testing, 15 by default |
With Delete punches after upload a punch accepted by the server (200) is removed from the reader. Without it, it stays on the reader marked as sent.
Server URL and HTTPS
http://works only to a server in the local network (10.x, 172.16-31.x, 192.168.x, 169.254.x, IPv6 fc/fd/fe80, or a name that points to such an address) and never over an open Wi-Fi.- For a server on the internet use
https://with a certificate from a public authority (e.g. Let's Encrypt), for example behind nginx or Caddy. - Keep the URL to plain characters (letters, digits,
- . _ ~ /). Some HTTP servers answer400to a URL with a stray%, and the reader drops such a punch.